Description
The Issue AP Report pop-up allows you to issue an anatomic pathology report. It contains the information needed to confirm that all necessary results, billing codes, ICD-10 codes and signatures are present to ensure maximum reimbursement.
Access
TaskCenter > Manage Testing > Work in Progress > double-click an AP entry to open AP Worksheet > Review and Issue button
Technical Manual
Billing Codes
Code | This column is populated by the CPT or charge code. |
---|---|
Item | This column is the item that added the code to the case.
|
Add Billing | Select this button to open the Add Bill-only Item pop-up.
Note Orchard Software recommends all CPT codes for Anatomic Pathology be set up as bill-only items. Adding bill-only items to a case is the only manner in which new CPT codes may be applied to the order, even if a CPT code is removed from the order by accident. To add bill-only items to the case, they must first be created on the Bill-only Items administration page. See Bill-only Items. AP cases can have multiple codes assigned to one bill-only item. |
Remove | Select the X to delete the billing item from the report. |
After Billing Rules
After Billing Rules Area | Use this area to see how rules will affect the billing codes and what will be printed on AP Reports and delivered to external billing systems. |
---|---|
Refresh | Select this button to rerun the rules and update the area. |
ICD-10 Codes
ICD-10 Codes Area | Use this area to see the list of ICD-10 codes. The codes are listed in bold font and are formatted with <code><space><hyphen><space><code description>. |
---|---|
Edit ICD-10s | Select this button to open the Edit ICD-10 Codes pop-up.
|
Signatures to be Reported
Performing Location | Select in or begin typing in this search-as-you-type field to search for and select the location where the pathologist read the slide(s) for the case. The location you select here will be tied to the added signature as its performing location. This is automatically populated to the user's signed-in location by default; however, you can change it if needed. |
---|---|
Action text | Use this drop-down list to choose one of the following action options:
Note You can set your default signature action text on the Users page so that the system will automatically select the text in the drop-down list that matches your role. |
Signing User | Use this drop-down list to select from a list of users who you have permissions to sign AP reports for. |
Add Signature | Select this button to add a row to the table based on options selected in the Action text and Signing User drop-down lists. |
Table | Use the Signatures to be reported table to view signatures for the AP report. The table has the following columns:
Note You can configure certain users to have their signature automatically appear in this table after selecting the Review and Issue button on the AP Worksheet pop-up. If the case already has a primary signature from another user, and no signature for the current user, the system will prompt the current user if they would like to add their signature as a secondary signature. For AP cytology order choices, the signature of the user with the highest AP cytology role will be assigned primary status. For example, if a primary screener initially signs the report and then a pathologist later signs it, the pathologist's signature automatically becomes the primary signature on the case when their signature is automatically added. The primary screener role is the lowest role, the QC screener is the middle role, and the pathologist is the highest role. |
Previous Report Signatures
This table lists signatures that have been previously included on issued reports.
Reported Date/Time | Use this column to view the date and time of the report that the signature was included on. |
---|---|
Report Type | Use this column to view the report type that the signature was included on. |
Signature Text | Use this column to view the signature text included on the report. |
Added By | Use this column to view the user that added the signature. |
Use this toggle button to print the signature on the next report. Set the button to on to print the signature on the next report. Set the button to off to leave the signature off the next report. |
Report Preview Area
This area displays a preview of the report. If the order has image tests that the system is configured to automatically annotate, those report image tests will display with annotations in this area.
Report Type | Use this drop-down list to select the type of AP report to be issued for the case. Prior to initial approval (issuing a final-level report), the options include:
After a Final report has been issued and a request that the case be reopened, the drop-down list options include:
If the case is currently in an amendment state, only Amendment report types will display. If the case is currently in an addendum state, only Addendum report types will display. |
---|
Buttons
Help | Select the question mark button located in the top-right corner to open the help files. |
---|---|
Expand | Select the expand button located in the top-right corner to make the Issue AP Report pop-up full screen. |
Request Rescreen | Note This button is only available for users who are Primary Screeners in anatomic pathology GYN cytology cases and when the Allow Primary Screener to send this case to be rescreened setting is enabled in AdminCenter > Order Choice Setup > Order Choices > Order Choice AP Setup > AP GYN Cytology Settings. Select the button to manually request that a case be rescreened. A confirmation pop-up will appear. Complete Case: Select the button to complete the case and close the Issue AP Report pop-up. |
Issue Report | Select this button (or press Alt+I) to apply any changes and issue the report. If the Report Type is Final, Addendum, or Amended, selecting this button will open the Issue Report Confirmation pop-up. Select Issue Report on the confirmation pop-up to proceed with issuing the report. The AP Worksheet will be placed in a closed state after issuing a Final report. When in the closed state, you cannot edit reported results, parts, or remove blocks/slides. Issue Report Warning: If there are linked order choices on the order that are not yet approved, you cannot sign out the case unless you have the appropriate permissions. An alert will appear displaying the test names (and their workflow status) that must be approved. If you have the appropriate permissions set up, you can select the Override and Approve button to issue the report before the other linked order choices are approved. This warning does not appear for preliminary reports. |
Issue Report and Close | Select this button to apply any changes and issue the report. The AP Worksheet closes, and you'll return to the Work in Progress page. The AP Worksheet will be placed in a closed state after issuing a Final report. When in the closed state, you cannot edit reported results, parts, or remove blocks/slides. Issue Report Warning: If there are linked or reflexed order choices on the order that are not yet approved, you cannot sign out the case unless you have the appropriate permissions. An alert will appear displaying the test names (and their workflow status) that must be approved. If you have the appropriate permissions set up, you can select the Override and Approve button to issue the report before the other linked or reflexed order choices are approved. This warning does not appear for preliminary reports. |
Save Signatures and Coding | Select this button to save the billing code, ICD-10 code, and signature changes without issuing the report. |
Cancel | Select this button to return to the AP Worksheet Pop-up. Any unsaved changes will be cancelled. |